Gallagher S100 Manual Del Usuario página 5

Portable solar
Ocultar thumbs Ver también para S100:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3E4207 Gallagher S100 Solar Energizer User Manual
be constructed so as to ensure that these wires are positioned at a minimum distance of 150 mm from
the vertical plane of the non-electrified wires. The barbed wire and razor wire shall be earthed at regular
intervals.
• Follow the energizer manufacturer's recommendations regarding earthing.
• A distance of at least 10 m shall be maintained between the energizer earth electrode and any
other earthing system connected parts such as the power supply system protective earth or the
telecommunication system earth.
• Connecting leads that are run inside buildings shall be effectively insulated from the earthed structural
parts of the building. This may be achieved by using insulated high voltage cable.
• Connecting leads that are run underground shall be run in conduit of insulating material or else insulated
high voltage lead-out cable shall be used. Care must be taken to avoid damage to the connecting leads due
to the effects of animal hooves or tractor wheels sinking into the ground.
• Connecting leads shall not be installed in the same conduit as the mains supply wiring, communication
cables or data cables.
• Connecting leads and electric animal fence wires shall not cross above overhead power or communication
lines.
• Crossings with overhead power lines shall be avoided wherever possible. If such a crossing cannot be
avoided it shall be made underneath the power line and as nearly as possible at right angles to it.
• If connecting leads and electric animal fence wires are installed near an overhead power line, the
clearances shall not be less than those shown in the table below.
Minimum clearances from power lines for electric animal fences
Power line Voltage V
Less than or equal to 1 000
Greater than 1 000 and less than or equal to 33 000
Greater than 33 000
• If connecting leads and electric animal fence wires are installed near an overhead power line, their height
above the ground shall not exceed 3 m.
This height applies either side of the orthogonal projection of the outermost conductors of the power line
on the ground surface, for a distance of:
-
2 m for power lines operating at a nominal voltage not exceeding 1 000 V;
-
15 m for power lines operating at a nominal voltage exceeding 1 000 V.
• Electric animal fences intended for deterring birds, household pet containment or training animals such as
cows need only be supplied from low output energizers to obtain satisfactory and safe performance.
• In electric animal fences intended for deterring birds from roosting on buildings, no electric fence wire
shall be connected to an earth stake. A warning sign shall be fitted to every point where persons may gain
ready access to the conductors.
• Where an electric animal fence crosses a public pathway, a non-electrified gate shall be incorporated in the
electric animal fence at that point or a crossing by means of stiles shall be provided. At any such crossing,
the adjacent electrified wires shall carry warning signs.
• Any part of an electric animal fence that is installed along a public road or pathway shall be identified by
electric fence warning signs (G6020) at regular intervals that are securely fastened to the fence posts or
firmly clamped to the fence wires.
Clearance m
3
4
8
5

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

G34610

Tabla de contenido