Replace hood and cover, guide the cable out of the
back of the device
The rinse water hose and the hose on the safety
overflow of the brine tank need to be mounted acc. to
DIN 1988 with at least 20 mm distance (free outflow)
to the highest possible drainage water level.
The pumping station needs to be constructed for a
water amount of at least 2 m³/h or 35l/min and be salt-
water proof. The pumping station needs to have a
greater capacity accordingly if it is used for other
plants as well.
4.3 Complying with the limit for the
sodium
When operating a softening device, the limit value for the
sodium concentration (acc. drinking water ordinance) of 200
mg/l may not be exceeded.
To reduce the water hardness by 1°dH, about 8mg/l sodium
needs to be added to the water. Additionally, the basic sodium
content* of the raw water needs to be taken into account.
The maximum possible softening results from these values.
Example:
Basic sodium content*
Limit value acc. to TVO
possible sodium dosage
possible softening
Result: the raw water hardness can be reduced
by 23.75 °dH.
* according to the water distribution company
5

Start-up

1.
Put diluting device into bypass position
• close the two outer valves
• open the middle valve
2.
Open shut-off valve on inlet
3.
Put diluting device into operating position
• Slowly open the input valve completely
• Slowly open the output valve completely
• Close middle valve
4.
Check that the water connections do not leak
5.
Pour water (about 1 litre) into the salt supply container
6.
Pour salt tablets into the salt supply container
CAUTION!
Use only salt tablets acc. DIN 19604.
7.
Connect transformer to the device
• Remove cover to the salt container and hood
• Plug the cable shoes of the transformer into the
controller
8.
Replace hood and cover, guide the cable out of the
back of the device
Naact. = 10 mg/l
Namax = 200 mg/l
Nadose = Namax - Naact =
190 mg/l
190 mg/l ÷ 8 mg/l = 23,75
GB
9.
Connect the softening device to the mains via the
transformer
10.
Programming the softening device
5.1 Programming the softening device
5.1.1 Display and operating keys
5.1.2 Basic settings for commissioning -
time, raw water
There is a connection to the power supply
Display Current time flashes
1.
Set the time by pressing +
2.
Confirm with MENU / OK
Display Hardness flashes
1.
Set the raw water hardness by pressing +
The hardness of the raw water can be inquired from
the water distribution company.
2.
Confirm with MENU / OK
• Display Regeneration time flashes
Factory setting for start time for regeneration: 2:00 AM
Start time can be modified by pressing +
1.
Confirm with MENU / OK
Display Clean flashes (KS10S-30)
4
or -
+
-
or -
+
-
and -
+
-
MU1H-1417GE23 R0420