D250S DUAL LAMP FUNCTION
LAMP
Power lamp
Alternator battery lamp
Service battery lamp
Solar panel lamp
D250S DUAL LAMP ERROR INDICATION
FUNCTION
D250S DUAL connected
correctly, ready to use
Alternator running
Charging of Service
battery
Solar panel in operation
Steady lamp
ExPLANATION
High temperature detected at either unit or ser-
vice battery
Service battery connection problem detected
Service battery connection problem detected
Service battery connection problem detected
D250S DUAL LAMP INDICATION
DURING NORMAL OPERATION
LIT wITh A STEADY GLOw
Service battery charged by the
alternator
Service battery charged by the solar
panel
Service battery charged by both the
alternator and solar panel
Service battery fully charged.
Alternator battery maintained by the
solar panel
Flashing lamp
RECOMMENDATION
Consider relocationg unit and/or service battery
Check Service battery connection and fuse
Check Service battery connection and fuse
Check Service battery connection and fuse
 EN • 9