Whirlpool JMW8330DAS Instrucciones De Instalación
Whirlpool JMW8330DAS Instrucciones De Instalación

Whirlpool JMW8330DAS Instrucciones De Instalación

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION
INSTRUCTIONS
30² WALL OVEN DESCRIPTION
1
1-1/4² Dia. Conduit Access Hole*
2
5/8² Plywood Floor (Must Support 250 lbs.)
DIMENSIONS
in
A
30 MIN
B
24 MIN
C
47 + 1/16
D
24 MIN
E
28-1/2 + 1/16
F
47-5/8
G
29-3/4
H
24-7/16
I
4 to 20
* Hole must be cut as close to corner of cabinet as possible.
NOTES
Z
Do not block air intake slots along bottom of oven.
INSTALLATION
1. Cut hole in cabinet to mount oven. Cutout in
cabinet should be level and straight.
NOTE: There are no provisions to level the unit
after it is installed. An oven that is not level could
cause poor baking results.
2. Install plywood floor as shown above.
3. Attach unit to the cabinet with 4 No. 8² flat head
screws supplied inside of envelope containing
these instructions. Pre-drill holes in cabinet for
attachment screws using 1/8² drill. Oven
mounting holes are provided in side trim.
4. See instructions "Electrical Connections" for
electrical hook-up.
5. See figure 1 for lower trim installation.
6. See User's Manual for operating instructions.
For European style cabinets (flush front) the required clearance for operation of the oven door is minimum
spacing of 7/8² between the cutout and the door, hinge or drawer of the cabinet.
Some built-in cabinets may not be wide enough, due to their construction, to allow this installation.
Built-In 30² ² ² ² Electric
Combination Wall Ovens
cm
76.20 MIN
60.96 MIN
119.38 + .16
60.96
72.39 + .16
120.97
75.57
62.07
10.2 to 50.8
CAUTION
403 WEST FOURTH STREET, NORTH
COMBINATION WALLOVEN CUTOUT
FIGURE 1
Remove lower screws from hinge receptacle plates. Align
lower trim and reinstall screws.
NOTE: Lower trim overlaps front edge of cabinet by 9/16².
NEWTON, IA 50208
8101P565-60
(07-03-00)

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Whirlpool JMW8330DAS

  • Página 1 Built-In 30² ² ² ² Electric INSTALLATION 403 WEST FOURTH STREET, NORTH Combination Wall Ovens INSTRUCTIONS NEWTON, IA 50208 COMBINATION WALLOVEN CUTOUT 30² WALL OVEN DESCRIPTION 1-1/4² Dia. Conduit Access Hole* 5/8² Plywood Floor (Must Support 250 lbs.) DIMENSIONS 30 MIN 76.20 MIN 24 MIN 60.96 MIN...
  • Página 2: Electrical Connections

    ELECTRICAL CONNECTIONS Unit to be properly circuit protected and wired according to local electrical code and National Electrical Code. It is advisable that the electrical wiring and hookup be Improper installation of the grounding accomplished by a competent electrician. circuit can result in a risk of electric 120/240 VAC or 120/208 VAC 60 Hz.
  • Página 3: Hornos Eléctricos Empotrados De Pared

    Hornos eléctricos INSTRUCCIONES 403 WEST FOURTH STREET, NORTH empotrados de pared DE INSTALACIÓN NEWTON, IA 50208 combinados de 30² ² ² ² CORTE COMBINADO DEL HORNO DE PARED 30² ² ² ² DESCRIPCIÓN DEL HORNO DE PARED 1-1/4² Diá. Orificio de acceso del conductor* 5/8²...
  • Página 4: Conexiones Eléctricas

    CONEXIONES ELÉCTRICAS El circuito de la unidad debe estar protegido y cableado ADVERTENCIA correctamente y de acuerdo con los códigos eléctricos locales y con el Código Eléctrico Nacional. La instalación incorrecta del circuito de Es recomendable que el cableado y las conexiones eléctricas las realice un electricista competente.
  • Página 5: Mise En Service

    Fours électriques mixtes MISE EN 403 WEST FOURTH STREET, NORTH encastrés de 30 po NEWTON, IA 50208, ÉTATS-UNIS SERVICE DÉCOUPE POUR LE FOUR ENCASTRÉ MIXTE DESCRIPTION DU FOUR ENCASTRÉ DE 30 PO Orifice d’accès de conduit de 1 1/4 po de diamètre* Plancher en contreplaqué...
  • Página 6: Raccordement À L'électricité

    RACCORDEMENT À L’ÉLECTRICITÉ Le circuit utilisé par l’appareil doit être correctement protégé et câblé conformément au code d’électricité local AVERTISSEMENT et au « National Electrical Code ». Une mauvaise réalisation de la mise à la Il est recommandé que le câblage et le raccordement électrique soient effectués par un électricien compétent.

Tabla de contenido