4.

CABLING

The SlimStone-X is equipped with a 2m long 2
conductor cable.
See p.70 for a detailed connection scheme.
EN
4.1 SYSTEM WIRING
Only copper cabling should be used for wiring the
system. The required cable diameter depends on
the maximum distance between the PowerStone/
DC-POWER 24V/25W and the furthest device in the
installation:
Maximum
one-way
distance between
PowerStone and
furthest device in the
network
25 m
100 m
300 m
Both the PowerStone or DC-POWER 24V/25W can
be used to power a network
_
BUS
+
24V DC
BUS 24V
AUX
POWER
OVERLOAD
L
N
Wiring when using a PowerStone
Wiring when using a PowerStone
L
N
220V
24V
DC-POWER 24V/25W
Wiring when using a DC-POWER 24V/25W
Wiring when using a DC-POWER 24V/25W
Bus wires have no polarity: there is no need
to take polarity (+ or -) into account when
connecting cables
10
Minimum cable section
2
0.2 mm
(AWG24)
2
0.75 mm
(AWG 18)
2
1.5 mm
(AWG 15)
BUS
BUS
C
NO
NC
R1
R2
C
NO
NC
IN1
IN2
BUS
BUS
C
NO
NC
R1
R2
C
NO
NC
IN1
IN2
4.2 SWITCHSTONE-STD
DETAILED WIRING
A
BUS
C
NO
C
R1
D
C
NO
IN1
E
R1, R2: 250 V~ / 24V ⎓, 16A
Power supply
A
Incoming power from PowerStone or
DC-POWER 24V/25W
Output to
B
Wiring to SlimStone-X
Relay
C
COM, NO and NC contact for relay 1
D
COM, NO and NC contact for relay 2
Control input
E
Control input for relay 1
F
Control input for relay 2
5.

SYSTEM INSTALLATION

• Connect the SlimStone-X to the SwitchStone-STD,
as described in the previous step
• After power-up, the waiting light sequence (see
figure 5. 1 ) will be shown. After a few seconds, [1]
will start flashing on the keypad, and [#] will be
permanently lit. On the SwitchStone-STD all lights
except the power light will be flashing.
B
BUS
NC
R2
NC
IN2
F
SlimStone-X