Description
SELECTO is an equipment preventing overcharge of the
bucket cylinders of the loader and permitting additional
hydraulic functions (one or two double-acting) for the
implements. These are electrically operated by the aid of
a switch, which is fitted on the loader joystick.
SELECTO (3)
This kit consists of:
- A valve (double-acting function)
- Parts required for the connection
- Electr.connectors / cables
The valve is equipped with 1/2" quick couplings. Setting
pressure of built-in security valves: 185 resp. 210 bar.
SELECTO (3+4)
This kit consists of:
- A valve with two double-acting functions. In other
respects, see SELECTO 3.
MOUNTING of SELECTO (3), (3,4)
Fig.A
Remove existing security valve. Secure the valve on the
cross tube of the loader by the aid of three screws (M6S
8 x 20).
Fig.B
Connect the oil pipes and hoses of the loader to the
bucket cylinders.
Fig.C
The connector (30) with bracket is standard in all hydrau-
lic kits (Ergodrive resp. Electrodrive).
Fig. D
Connect cable between connector and valve according
to fig. D.
A
D
ENGLISH (112-501)
Fig.E
Connect the cable from the electric control device acc. to
the wiring diagram (the leaders are marked 1,2,3).
The connector (30) shall be connected to the current
source(12V+) and the earth wire to the tractor body.
WARNING !
Incorrect installation of the cables will destroy the built-in
diodes in the connectors on the valve.
REMARK !! Connect after the tractor safety switch. The
electr. cables are supplied with a fuse (8A) to be fitted on
the leader (+) between connector and current source.
Make sure that the connection point is dimensioned for
the power consumption of the valves (5A).
To achieve the "right" function, the connectors (26) shall
be connected acc. fig. D.
Note ! connect the black cable with connector to the right
side (3rd function) of the valve. The red cable with
connector is aimed for the 4th function.
IN GENERAL
After the fitting, fasten the electr. cables by the aid of
supplied strap in order to prevent these from being
exposed to wear / squeezing.