Adjusting the Temperature (continued)
5
Reinstalling the red limit stop ring
□
Reinstall the red limit stop ring (1) and readjust
the teeth engagement position so that the stem
cannot move beyond the adjusted point.
6
Reinstalling the inverter, sleeve
and handle
NOTE: Rotate the cartridge stem (4) clockwise to turn off
the water before you install the handle.
□
Place the inverter (1) onto the valve body (D) and
rotate the inverter (1) with notch facing down and
reinstall the stem adapter and screw. Then
secure with the screw (2).
□
Screw the sleeve (3) onto the valve body (D).
□
Place the handle (F) onto the valve body (D)
and secure with the set screw (G).
Care and Cleaning
□
To clean, wipe down with a damp cloth and dry with a towel.
□
Do not use abrasive cleaners, steel wool, or harsh chemicals when cleaning this faucet, or the warranty will
be voided.
1
3
F
G
14
1
2
4
D