installation (continued)
3
Feeding the wires
nOTe: Put the gasket (BB) on any knock out hole of the fixture to better protect the wires.
□ Feed the electrical connection wires through any knock
out hole and then through the mounting bracket (AA). The
connection wires can be held in place by the metal tabs,
if needed.
BB
4
Making the electrical connections
□ Connect the hot and neutral (black and white) wires
from the housing (A) to the same color wires from the
electrical box.
□ Cover the wire connection using the double wire
connector (CC).
□ Connect the green wire from the housing (A) to the
grounding wire from the electrical box. Secure together
using a single wire connector (DD).
DD
5
CC
AA
A
6
Knock out holes
Metal tabs
Attaching the mounting bracket to
the electrical box
□ Position the wires back inside the electrical box.
□ Mount the mounting bracket (AA) to the electrical box
using the two electrical box screws (EE).
DD
EE
AA
CC
AA