Troubleshooting

Before doing any work on the fixture, disconnect power to the light fixture.
WarninG:
Minor problems often can be fixed without the help of an electrician.
Problem
The fixture will not light.
The fuse blows or the
circuit breaker trips when
the light is turned on.
The light is not staying on
long enough after the last
motion is detected.
The light is staying on too
long after the last motion
is detected.
The motion sensor is not
detecting motion in a
large enough area.
The motion sensor is
detecting motion in too
large an area.
The motion sensor is
detecting motion during
daylight hours and turning
the light on when I do not
need it on.
The motion sensor is not
detecting motion and
turning the light on during
daylight hours when I
need it to.
Possible Cause
The power is off.
The circuit breaker is off.
There is a bad connection.
There is a defective switch.
The wires are crossed or
the power wire is grounding
out.
The hold-time setting needs
to be adjusted.
The hold-time setting needs
to be adjusted.
The motion sensor needs to
be adjusted.
The motion sensor needs to
be adjusted.
The daylight sensor needs
to be adjusted.
The daylight sensor needs
to be adjusted.
Solution
Ensure the power supply is on.
Ensure the circuit breaker is in the on position.
Check to ensure proper wire connections are made. Contact a qualified
electrician.
Contact a qualified electrician.
Check the wire connections.
Contact a qualified electrician or call Commercial Electric customer service
1-877-527-0313.
Factory setting is a 5 minute hold time. To
increase the time period the light remains
on, please refer to page 8 of the instruction
manual to adjust the 4th dip switch to the
preferred setting.
Factory setting is a 5 minute hold time. To
decrease the time period the light remains
on, please refer to page 8 of the instruction
manual to adjust the 3rd and 4th dip
switches to the preferred setting.
To increase the motion detection area,
please refer to page 8 of the instruction
manual to adjust the 1st and 2nd dip
switches to the preferred setting.
To decrease the motion detection area,
please refer to page 8 of the instruction
manual to adjust the 1st and 2nd dip
switches to the preferred setting.
Ensure the 5th and 6th dip switches are
set to detect light at the 50 lux, 10 lux or 2
lux settings. Please refer to page 8 of the
instruction manual to adjust the 5th and 6th
dip switches to the preferred setting.
Ensure the 5th and 6th dip switches are
set at "disable". This will allow the light
to turn on when motion is detected at any
light level. Please refer to page 8 of the
instruction manual to adjust the 5th and 6th
dip switches to the preferred setting.
9
Please contact 1-877-527-0313 for further assistance.
IV
15 min.
I
5 sec.
n
n
II
90 sec.
n
I
100%
n
n
III
50%
n
IV
10%
II
50 lux.
n
III
10 lux.
n
IV
2 lux.
I
Disable
n
n