CONTROL PANEL NE144F
GB
CONTROLS:
Push button with warning light for turning INTERNAL LIGHTS on or off
IN
Push button with warning light for turning EXTERNAL LIGHTS on or off
OUT
Push button with warning light for turning PUMP on or off
Push button with warning light for turning AUX on or off
AUX
SCREENS:
The main screen always shows the date, time, internal and external temperatures. If there
is no temperature probe, or the existing one is faulty, three dashes are displayed instead of
the temperature reading. If the network is connected, the display shows the (
CHECK
Display contrast can be adjusted by turning the white pin located on the back of the panel.
Key for viewing the level of drinking water in tank S1 and the recovery tanks R1.
Optional:
If the "litre probe" (mod. NE131) is used on the S1 tank the measurement is no
longer indicated as level, but is linear with an indication of the litres.
The screen remains active for approx. 30 seconds.
Press the button again to view the service battery and start battery voltage.
Optional:
If the amperometric shunt accessory is used, press the key twice to see the
screen for reading the service battery loading voltage or discharge.
The screens remain active for approx. 30 seconds.
PROGRAMMING:
Hold this key down for over two seconds to enter the programming menu. Use the arrow
keys to change pages. Press the enter key (
value to be edited. Use the arrow keys to increase or decrease the selected value, and the
CHECK
cancel (
) key to exit the function and save the value.
The pages available are:
-Regulation of time and date
-Regulation and enabling of alarm clock. When the alarm clock is enabled a bell
appears on the screen. The alarm clock rings for 30 seconds. Strike any key to
stop it ringing.
-Alarm enabling: drinking water tank is empty, recovery tanks are full. This situation
generates an alarm that sounds intermittently for 5 seconds. At the same time the
display shows the tank-viewing window.
-Alarm enabling: service and auto batteries discharged. Whenever the auto battery
goes below 11V or the service battery goes below 10V it generates an alarm that
sounds intermittently for 5 seconds. At the same time the display shows the battery
voltage-viewing window.
-Key beep enabling.
CONSUMPTION:
Press the (
) key to turn on the control panel. In the stand-by mode (controls not active) the control panel with the
NE185 shunt consumes a total of approx. 36mA. When the (
consumption can be reduced to just 11mA.
If the service battery voltage drops below 9.5V the control panel automatically turns itself off.
MEMORY BATTERY:
A buffer battery (LITHIUM 3V CR2032) is located on the back of the panel to maintain the time and various program
settings in the event of a power breakdown.
DIMENSIONS: (L x H) 250 x 120 mm
) repeatedly to enter the page and select the
) key is held down for over 3 seconds, total
GB
6
) symbol.
GB