  • ESPAÑOL, página 14
Automatic Water
System Pump
CAUTION
Not For Continuous Duty, Intermittent
Duty Only
Installation/Mounting
1: Remove shipping plugs from the pump ports.
2: Connect fittings supplied with the pump to the vessels
plumbing. Use
braided or reinforced) to reduce vibration through the
plumbing system
(Figure 1). Use
hose clamps on
the slip on barb
hose connectors.
Important:
Install a strainer
in an accessible
location (for
inspection
and cleaning)
between the tank
and the pump inlet to
protect valves from debris.
3: Fasten pump to a flat surface. If
mounting vertically; install with pumphead down (Figure 2)
Do not over tighten screws to allow rubber mounts to absorb
vibration.
Figure 2.
Horizontal
4: Install inlet (A) and discharge (B) fittings. Firmly push slide
clips (C) forward to lock fittings in place. – Figure 3
Figure 3.
Inlet Port
Fitting
Side Clips
Figure 4.
Water
Tank
/
" (19mm) I.D. flexible hose (preferably
3
4
Outlet Port
Jabsco
City Water
Regulator
Pumpgard
Figure 1.
Vertical
NOTE: Do Not Submerge
Fitting
Water
Heater
Check
Valve
TM