Once you have set the hysteresis, wait five seconds until the switching differential symbol stops
flashing.
The room thermostat only regulates once the temperature falls below the temperature set-
ð
point by the amount of the hysteresis that was just set.

Actuator (receiver)

INSTALLATION IN A FLUSH-MOUNTED SOCKET

Personal:
Qualified electrician
Removing the housing cover
1.
Undo the screw connection on the device housing with the Phillips screwdriver and remove the
housing.
Connecting
2.
Strip the connection wires to a length of 8 mm (cross-section between 1 mm² and 2.5 mm²).
3.
Insert the connection wires into the corresponding terminals (Fig. 2/6) in accordance with the
wiring diagram (Fig. 7).