INSTALLATION DIAGRAM
ELECTRONIC CONTROL EQUIPMENT REP RCU1 -115V-
ELECTRICAL CONNECTIONS
FUSES F1 : 160 mA (24V)
F2 : 10 A (Mains)
LK1
- Programming jumper
- Link - Programming mode
- Release - Use mode
Turn OFF electrical power and turn it ON again, if any kind of job is necessary on the LK1.
DL1 START LED
DL2 Photocell LED
Key-operated selector
switch (optional)
J1 TERMINAL BOARD MAINS TERMINAL BOARD
E - Earthing terminal. Connect the electrical mains earth connection + 2 earth connections of the
motor
N - Mains neutral terminal
L - Mains phase terminal
J2 TERMINAL BOARD OUTPUTS TERMINAL BOARD 115 VAC (Motor + flashing-lamp)
6 - Opening Output - Motor + Capacitor wire
7 - Common Output - 1
8 - Closing Output - Motor + Capacitor wire
9 - Opening Output - Motor + Capacitor wire
10 - Common Output - 2
11 - Closing Output - Motor + Capacitor wire (closing delay)
}
12 -
115 VAC Output - For lamps with flashing-lamp device Type E27 40 W
13 -
J3 TERMINAL BOARD LOW VOLTAGE TERMINAL BOARD
1 - "-" Terminal, common for all accessories (- photocells)
2 - Antenna input
3 - START Input (dry, pulse contact)
4 - Photocell Receiving Signal Input
5 - "+" Terminal, power supply to accessories (+ photocell)
- In the case of single-leaf gates, the motor must be connected to 6-7-8
- Delay time must be programmed to 0 seconds (DIP 4: OFF - DIP 5: OFF)
- If no motor is connected, the cycle will not start.
- Cable clamps ensuring an IP55 protection class shall be used for the cable entrance into the
control unit when the unit is placed outside
7
- Normally OFF - it goes ON if the START command is given or if
remote-control is used.
- Normally ON - it goes OFF when the photocell beam is interrupted.
- The photocells are active when the gate is closing. If the beam is interrupted,
the gate re-opens.
- No effect during opening.
}
115 VAC
}
st
leaf Motor
1
st
leaf
nd
leaf Motor
ENGLISH
}
nd
2
leaf