IMPORTANT REMARKS
• Attention: for people safety it is important to follow carefully
the instructions. Keep the instructions.
• Important safety instructions for the installation.
Attention: a wrong installation can cause serious accidents.
Follow carefully the installation instructions .
• This device can be installed only from qualified persons.
• The control buttons and the connection cables shall have
insulation properties suitable for electrical installations with
operating voltage of not less than 300Vac
• In order to protect the device, the installer must provide for
a magnetotermical differential switch (separation among the
contacts: at least 3 mm), ensuring the omnipolar sectioning
from the power supply.
• The device must be installed only inside a junction box or wall
box.
• The device container does not provide any protection
against water. Thus, it should be installed only in protected
environments.
DISPOSAL
As for the installation operations, even at the end of this product's
life span, the dismantling operations must be carried out by
qualified experts.
This product is made up of various types of materials: some can
be recycled while others need to be disposed of.
Find out about the recycling or disposal systems envisaged by your
local regulations for this product category.
Important! – Parts of the product could contain pollutants or
hazardous substances which, if released into the environment,
could cause harmful effects to the environment itself as well as to
human health.
As indicated by the symbol opposite, throwing away this product
as domestic waste is strictly forbidden. So dispose of it as
differentiated waste, in accordance with your local regulations,
or return the product to the retailer when you purchase a new
equivalent product.
Important! – the local applicable regulations may envisage heavy
sanctions in the event of illegal disposal of this product.
EU DECLARATION OF CONFORMITY
V2 S.p.A. hereby declare that products DEV-R2 conform to the
essential requirements established in the following directives:
- 2014/30/UE (EMC Directive )
- 2014/35/UE (Low Voltage Directive)
- 99/05/CEE (Radio Directive in accordance with standard
EN 301 489-3)
- ROHS2 2011/65/CE
Racconigi, 01/06/2019
V2 S.p.A. legal representative.egale della V2 S.p.A.
Sergio Biancheri
DESCRIPTION
The DEV-R2 module allows to control a load of up to 500W in
monostable, bistable and timer mode.
The small size of the container allows the module to be easily
inserted inside the switches.
• Power supply with extended range: 85 ÷ 260 Vac - 50/60 Hz
• Very low power consumption in stand-by
• 434.15 MHz radio receiver with integrated antenna
• Programmable through a button or PROTEO transmitters
• Compatible with SCREEN transmitters
• Stores up to 30 radio channels
• Two wired inputs: up and down
• Relay output with no-voltage contacts for loads of up to 500W
• Integrated button for programming operations
• Wireless programming via a remote control provided with
memory
SPECIFICATIONS
Power supply ______________________ 85 ÷ 260 Vac - 50/60 Hz
Consumption in stand-by ____________ 0,25 W
Maximum relay load: _______________ 5A (cosj = 1)
Operating temperature ______________ -20 ÷ +60 °C
Protection _________________________ IP10
- 8 -
- 8 -
2A (cosj = 0,4)