Initial set up:
Make sure that shutter can move freely. Obstacles, e.g. flowerpots on the outer window-sill, are to be
removed. Make sure that stoppers/conical stops are existent and that these have a firm connection
with the shutter. Now push any one of the three buttons of the shutter strap motor (fig.14). In the fol-
lowing the window size is automatically measured, i.e. defining of upper- and lowermost limit. The
shutter strap motor will pull the shutter up until the conical stops reach the shutter box (or wall). A
humming sound indicates the correct functioning of the motor.
Then the shutter will be lowered automatically until completely closed and the lower limit is defined.
Finally the shutter will be opened again automatically and will stop shortly before reaching upper limit.
Attention: The automatical measuring cannot be interrupted. Should this process be interrupted
through power failure or should the plug be pulled accidentally, start over again = push any one of the
three buttons.
After completing this process the initial set up is finished. The shutter can be opened or closed by
pushing the Open- or Close-button ( fig.14).
Safety function:
If obstacle is hit or shutter profiles are tilted the GWAP120 will shut down automatically. This avoids
personal or property damage.