Configuration of the switching inputs
Functional characteristics
[Display indicator]
Active call number
[Act. call no.]
Active function
[Act. fct.]
Passive call number
[Pass. call no.]
Passive function
[Passiv fct.]
Configuration of the switching outputs
Functional characteristics
[Display indicator]
Switching function
[Switch]
without time setting
Time relay
[Timer]
Time setting: 0.4 s – 90 s or
2 min. – 19 min. (default: 0.4 s)
Door release
[Door release]
Time setting: 0.4 s – 90 s or
2 min. – 19 min. (default: 0.4 s)
Light
[Light]
Time setting: 0.4 s – 90 s or
2 min. – 19 min. (default: 0.4 s)
Monitor *
[Monit. user[x]]
without time setting
Secondary signal controller *
[SSC user[x]]
Time setting: 0.4 s – 90 s or
2 min. – 19 min. (default: 0.4 s)
Door dialling
[Door select.] (only for DCA 612-...
in conjunction with special wiring in
the 1+n system)
* There is a fixed assignment
between the user and relay number
(e.g. user 2 = relay 2)
Behaviour
Individual call number
(max. 22-digits) is dialled when
triggered.
One or more pre-programmed
functions are carried out when
triggered.
Individual call number
(max. 22-digits) is dialled when
triggered.
One or more pre-programmed
functions are carried out when
triggered.
Behaviour
Switch on and off each through
manual trigger via different DTMF
codes.
Switch on through manual trigger via
DTMF code, switch off takes place
after configured time setting. Manual
switch off can also be configured.
Switch on through manual trigger
via DTMF code, switch off takes
place after configured time setting,
parallel to door release function of
the door call system.
Switch on through manual trigger
via DTMF code, switch off takes
place after configured time setting,
parallel to light switch function of
the door call system.
Switch on via automatic trigger.
Automatic switch off once com-
plete.
Switch on via automatic trigger.
Switch off takes place after config-
ured time setting.
A door station can be selectively
manually dialled with the configured
switching output.
Trigger
• Active state change at the
switching input (low -> high):
voltage 5–30 V DC or 4–20 V AC
was applied
• Passive state change at the
switching input (high -> low):
voltage no longer present
Trigger
• Configured switching input with
active and passive function
• DTMF dialling via telephone
• Configured switching input with
active function (passive function if
to be manually switched off)
• DTMF dialling via telephone
• Configured switching input with
active function
• DTMF dialling via telephone
• Configured switching input with
active function
• DTMF dialling via telephone
• Configured user and incoming
door call or active door call
• Configured user and incoming
door call
• Configured switching input with
active function
• DTMF dialling via telephone
9