Measurements memory
The range-finder was fitted with a memory, where the results of last 20 measurements are automatically saved. Older
results are deleted and automatically replaced with newer ones. To preview the results saved start the device and press
the measurement memory button. Repeated pressing will allow previewing last 20 measurement results. Along with
results, display will show the number of a memory register.
Continuous angle measurement
The range-finder measures continuously the angle of range-finder inclination. The measurement is made by means
of internal position sensor and operates even with laser indicator off. The result of measurement is displayed on the
screen.
Acoustic signal
By pressing a button marked with a symbol of loudspeaker you enable or disable acoustic signals.
Error messages
Error code
Cause of error
204
Calculation error
208
Excessive current
220
Low battery level
252
Temperature is too high
253
Temperature is too low
Return signal is too weak
255
or time of measurement is
too long
256
Return signal is too strong
261
Out of measurement range
500
Hardware error
Solution
Repeat the measurement procedure according to instruction
Contact the technical service
Replace batteries or charge the storage cell
Cool down the device
Heat the device
Change the measurement surface
Change the measurement surface
Object must stay within measurement range
Repeatedly switch in and off the device. If the error persists please contact the technical service