hager EE600 Manual De Instrucciones página 11

Ocultar thumbs Ver también para EE600:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29
Adjustments
a
b
Detection zones
vue 30-30°
2,5 m
Ø 6 m
Optimal installation height is 2.5m.
The detection zone shall remain free of obstacle.
8
Fixed time
(length of time
of lighting)
c
8 m
12 m
Luminosity
Sensitivity
(modification
of the range)
vue 30-30°
Testing and validating
the detection zone
Put the potentiometer
on Test mode and
2
if necessary, use the shutters to define the
detection zone.
ech40%
The Test mode is available for 3 min. Every
movement detected switches on the light for 1s.
After 3 min without detection of movement, the
product returns to normal operation.
"Normal" operation (on/off)
The light panel switches on when the luminosity
level defined by potentiometer 2 is judged to be
insufficient and when a movement is detected.
After detection, the light stays on for the length
of time predefined by the potentiometer 1. The
fixed timing is reset after each detection.
Please note : when the potentiometer 2 is on
"auto test", the settings are predefined (See table
below).
z

Publicidad

Tabla de contenido
loading

Productos relacionados para hager EE600

Tabla de contenido