5.
To support the OS826, the ProGuard800's Main board must have the on-
board transmitter installed. Plug the on-board transmitter into the control
panel's Main board as shown in Figure 3.
Note: Power down the control panel before plugging in the on-board transmitter.
6.
On the control panel, define the siren type as "2-Way Siren" as follows:
• From the Programming menu, select Devices, Siren, Ext. Siren Type
[9152].
• Select "2-Way Siren".
• Define the siren delay
• Enter a siren delay time (00-59 sec).
7.
Define the Siren Cut-off as follows:
• From the Programming menu, select Devices, Siren, Cut-Off [9154].
• Enter a siren cut-off time (00:10 - 20:00 minutes).
8.
Set the siren to Registration mode by placing the Mode jumper (JP1) as
shown in Figure 4.
OS826
Terminals 1 & 2: External Tamper Input
Terminals 3 & 4: Power Input
Terminals 5 & 6: Siren Output
Terminals 7 & 8: Back Tamper Input
Figure 2: Wiring Connections
Figure 3: Plugging in the On-Board Transmitter