Use and maintenance manual | Series MILLENNIUM
4) MANUAL STARTING PROCEDURE OF REGENARATION
Based on customer requirements, a regeneration process can be started manually at any time. In this case, you
will notice that, during the regeneration process, the softener will deliver unsoftened water.
To proceed with manual regeneration, follow the steps below:
Press and hold the buttons at the same time
pad is unlocked.
Press the button
and immediately the regeneration process will start.
2.2.6 Section for technical personnel
It is possible to access the programming of the regeneration times in the various phases.
Changing these settings defined by the manufacturer seriously compromises the functionality of the softener, so
please do not do so.
If these settings have been changed by the customer, you can reset the original data as follows:
REGENERATION CONTROL MODE
FREQUENCY OF COUNTER-CURRENT WASHING
QUANTITY OF SOFTENED WATER
WASHING TIME COUNTER-CURRENT
46
for 5 seconds until you hear the beep and the key
m
m
A – 01
F – 07
Millennium 8 (0.55)
Millennium 12 (1.10)
2 – 01

Publicidad