warning
WARNING
Avoid the penetration of water into parts of the system during periods of inactivity to avoid the risk of short
circuits or malfunctions.
In case of emergency / danger the system can be stopped:
1) by disconnecting the power supply unit;
2) by activating the by-pass.
This will immediately stop the system.
2.4 Restarting after long periods of inactivity
Always have a qualified and specialised technician check that the system has maintained at the original
degree of protection of the electrical equipment.
Connect the power supply unit to the machine and check that the timer is working.
Slowly open the water inlet valve and then start forced regeneration.
Place 10 litres of lukewarm water and 50 ml of Amuchina in the salt container.
Wait for the end of regeneration (not before two and a half hours), then open the water outlet valve and
close the bypass valve.
Use and maintenance manual | Series MILLENNIUM