1.4. Assembly of the completion set ref. no. 27410.3

One sided connections at the heat generator / Thermix mountable on the left of the wall mounted boiler
1. Seal the clamp screw connection (1) into the shut-off
fittings of the heat generator.
2. Insert and slightly tighten the T-piece (2).
3. Drill the wall holes (3) according to the illustration. Thermix
is positioned on the left of the wall mounted boiler.
4. Uncase Thermix from the insulation and first connect
and tighten the corrugated pipes (4) onto Thermix with a flat seal
ATTENTION: If using the completion set Taco, the corrugated pipe in the supply flow of the pipe connection group has to be exchanged with
the VL and RL kits and connected and tightened to Thermix with a flat seal. (Attention! Observe flow direction; select the corrugated pipe
lengths according to assembly space).
see Fig. 4.4, 4.4.1 and 4.4.2
1.5. Assembling completion set Taco in VL + RL ref. no. 27410.4
Exterior connections at the heat generator, Thermix mountable to the left or right of the wall mounted boiler with volumetric flow limiters.
1. Seal the clamp screw connection (1) in the shut-off
fittings of the heat generator.
2.Insert and slightly clamp the T-piece (2) into the clamp screw
connection (1).
3. Drill the wall holes (3) according to the illustration.
4. Uncase Thermix from the insulation and first connect
and tighten the corrugated pipes (4) onto Thermix with a flat seal (on
primary side; towards the heat generator).
ATTENTION: If using the completion set Taco, the corrugated pipe in the supply flow of the pipe connection group has to be exchanged with
the VL kit (Attention! Observe flow direction) and subsequently connected and tightened to Thermix with a flat seal. Remove lower clamp
screw connection (screw nut and clamp ring) at the T-piece (2) in the return flow. Insert push-in socket (5) and connect the RL kit with a flat
seal to the T-piece. (Attention! Observe flow direction)
see Fig. 4.5, 4.5.1 and 4.5.2
Fig. 4.5.2

2. Wall mounting

see Fig. 5, 5.1 and 5.2
Effiziente Energietechnik
(on primary side; towards the heat generator).
5. Bend the corrugated pipes into the desired position and connect
to the T-piece with a flat seal.
6. Tighten all connections.
7. Cut out the pre-cut rated break points before attaching
the upper part of the insulation.
5. Mount the wall mounting according to the description in
chapter „2. Wall mounting".
6. Bend the corrugated pipes into the desired position and
connect to the T-piece with a flat seal.
7. Tighten all connections.
8. Cut out the pre-cut break points before attaching
the upper part of the insulation.
Fig. 4.5
A Kit - VL
C Kit - RL
Fig. 4.5.1
A Assembly on the left (Inverse assembly on the right)
A Kit - VL
B Kit - RL
Fig. 5
Screw the bracket tightly to Thermix. The spacers
must be used.
Fig. 5.1
Connect the wall mounting bracket to the
bracket, which is already on Thermix, by means
of screws.
Fig. 5.2
After assembly of both brackets, Thermix can be
hung on the screws on the wall. Tighten the screws.