4
End limits adjustment
If the installation includes several motors, only one motor is to be powered during this programming procedure.
It will avoid interferences with the other motor during the procedure.
4.1- Learning mode:
- Switch ON the motor.
- Simultaneously press the UP and DOWN keys of a Hz transmitter. The
motor will run for 0,5 second in one direction and then in the other.
The transmitter now controls the EHz motor in unstable mode. Go
to stage 4.2.
4.2- Check the rotation direction:
Press the UP key of the transmitter:
a- If the motorized tube runs in the UP direction , go to next stage (4.3).
b- If the motorized tube runs in the DOWN direction, reverse the rotation direction by pressing the STOP key for at least 3 seconds.
The motor will confirm the reversal of the rotation direction by running 0,5 second in both directions. Go to stage 4.3.
a
>>
4.3- Adjustment of the end-limits - memorizing the end points:
The end limits of the T5EHz are adjusted in 4 different ways depending on the following conditions :
- Bottom slat stop or not, rigid* or flexible link between the rolling shaft and the shutter.
A
*V.A.R
V.A.S
A
1
B
1
1- Move the motor to the UP end limit by using the keys UP or DOWN.
2- To memorize the UP end limit position, press simultaneoulsy the keys STOP and DOWN. The motor will run automatically in
the DOWN direction.
3- Press the STOP key to immobilize the motor.
4- Press 2 seconds the STOP key to confirm the adjustment. The motor will run for 0,5 second in one direction, then in the other
direction. Go to stage §5.
C
1
1- Move the motor to the DOWN end limit by using the keys UP or DOWN.
2- To memorize the DOWN end limit position, press simultaneoulsy the keys STOP and UP. The motor will run automatically
in the UP direction.
3- Press the STOP key to immobilize the motor.
4- Press 2 seconds the STOP key to confirm the adjustment. The motor will run for 0,5 second in one direction, then in the
other direction. Go to stage §5.
2/4
OK
4.3
>>
>>
b
B
*V.A.R
V.A.S
2
1- Simultaneously press the UP and DOWN keys of a Hz transmitter. The motor
will run for 0,5 second in one direction and then in the other.
2s
2- Press the "stop" key for 2 s. The motor will run for 0,5 second in one direction
and then in the other. The operation is completed. Go to stage §5.
3s
>>
C
2
2
ON
>>
>>
D
3
3
>>
OK
4.3
>>
4
2s
4
2s