D
1
1- Move the motor to the DOWN end limit by using the keys DOWN or UP.
2- To memorize the DOWN end limit position, press simultaneoulsy the keys STOP and UP. The motor will run automatically in
the UP direction.
3- When the motor reaches the UP End limit, press the key STOP.
4- If necessary adjust the position with the keys UP or DOWN.
5- To memorize the UP end limit position, press simultaneoulsy the keys STOP and DOWN. The motor will run automatically in
the DOWN direction.
6- Press 2 seconds the STOP key to confirm the adjustment. The motor will stop, and will run for 0,5 second in one direction,
then in the other direction. Go to §5.
- After these operations, you can program the transmitter used before as a 1st control point. To do so, see
chapter §5.
- If you do not want to keep this transmitter and program it, switch the power supply off. When you will pro-
gram another transmitter with this motor (example : after the shutter installation) refer directly to chapter
§4.1. In this case, when you switch on the power supply, the motor must run for 0,5 second in one direction
and in the other. That indicate the end limits are adjusted but the controls are not programmed. Then go to
stage §5 for programming.
5
Programming the first individual control point
- This operation can only be performed from the transmitter that was used for operation 4.1.
- Press the transmitter "PROG" Key for approximately one second.
The motor will run for 0,5 second in one direction and then in the
other. Your transmitter is now programmed to control the EHz
motor in stable mode.
6
Recording and control of the intermediate position
Recording:
- Move the motor to the wanted
position.
- Press 5 seconds on the "stop" key.
The motor will run for 0,5 second in
one direction and then in the other.
7
Programming a new (individual, group or general) control point
7.1- Open the memory of the receiver from the control transmitter:
- Press the "PROG" key of the transmitter for about 3 seconds. The motor
will run for 0,5 second in one direction and then in the other.
7.2- Confirm the operation from the new transmitter you want to
program:
- Press the "PROG" key of the transmitter for 1 second. The motor will run
for 0,5 second in one direction and then in the other.
- For group controls, repeat operations 7.1 and 7.2 for each motor in the group.
- For general controls, repeat operations 7.1 and 7.2 for each motor in the installation.
- To delete an transmitter from the memory of a motor, perform operations 7.1 with a programmed transmitter, then perform
the operation 7.2 with the transmitter to be deleted.
2
3
5s
4
Control:
- Press the "stop" key for 0,5
second. The motor runs to
the intermediate position.
5
≥1s
>>
PROG
0,5s
≥3s
>>
PROG
≥1s
>>
PROG
6
2s
3/4