Troubleshooting Procedures (cont.)
Symptoms
"Err 6" appears on the
6.
control pad.
"Err 7" appears on the
7.
control pad.
"Err 8" appears on the
8.
control pad.
9.
Unit shuts off.
10. No steam is being
generated.
11. There is a continuous
flow of water from the
steam head. (Water flow
during automatic purge
cycle is normal.)
Kohler Co.
Probable Causes
B. Water feed assembly is blocked.
A. Indicates float switch tripped
for 10 seconds.
A. "Temperature" button is stuck.
A. "Clock" button is stuck.
A. Unit has been in operation for
more than 20 minutes.
A. Piping not properly attached.
B. Steam head blocked.
A. Water supply incorrectly
attached to steam generator.
B. Water feed assembly is stuck.
5
Recommended Action
B. Remove and inspect the water feed
assembly in the generator.
A. Shut off the system and allow it to
cool.
A. Reset the power at the breaker.
A. Reset the power at the breaker.
A. Turn unit back on.
A. Reattach the pipes properly.
B. Remove the steam head (after
cooling) and check that the plunger
slides freely in the cap.
A. Connect the water supply to the
proper inlet.
B. Remove and inspect the water feed
assembly in the generator.
1008019-5-D