TIMER RESET PROCEDURE
warning
IMPORTANT
Perform reset procedure only if recommended by the supplier, the manufacturer or, ideally, be assisted directly by a skilled techni-
cian, also by phone.
TO RESET THE TIMER:
1. Keep SET and DOWN simultaneously pressed for 5 seconds.
2. H0 and the programme set by the system (7÷16/F) will be
displayed.
3. If a historical value other than "H0" is shown, use the arrow
UP to scroll the settings until "H0" appears.
4. To reset the timer, keep SET pressed for 5 seconds.
5. The timer will be reset at a non-programmed state.
6. Go to "initial setting" section to reprogram the timer.
warning
WARNING
Timer reset will erase all recorded information. This means that it will be necessary to completely reprogram the timer from initial
starting mode.
For further information about the equipment performance, see the Manufacturer's Manual of instructions, use and
maintenance.
INSTRUCTIONS FOR THE INSTALLATION OF RESIN DISINFECTION SYSTEM
Programmers Logix 740C/742C e 760C/762C are conceived in order to control a device for the production of chlorine
(optional), which allows to disinfect the resin bed after each regeneration.
There is an alert indication for lack of salt. The installation of the chlorinator is simple.
STEP 1
Remove timer Logix from the valve and take power off.
10
RESET PROCEDURE FOR LOGIX TIMER
TIMER DISPLAY AFTER RESET
CHLORINATOR
CONNECTION
(VERSIONS
740C/742 AND
760C/762C)
TIMER LOGIX - BACK