INSTALLATION INSTRUCTIONS
STEP 3
For best results, use a Cadet electronic wall thermostat or an EBKN double pole thermostat kit. It is recom-
mended that a thermostat be provided for each room. The location of the wall thermostat should be selected
carefully. Thermostats should not be located near drafts from an open doorway or within 18" (45.7cm) of an
outside wall, or in direct sunlight or unusual heat sources. A television set or appliance that builds up heat near
a thermostat will prevent the thermostat from functioning properly. A wiring diagram illustrating typical wiring of
the thermostat is included in the literature provided with the thermostat.
Illustrated in Figures 8 through 12 are wiring diagrams typical of a single unit controlled by a single pole ther-
mostat, a single unit controlled by a double pole thermostat, and two units controlled by a double pole thermo-
stat.
Single Pole
Single Pole
Thermostat
Thermostat
Single Pole
Single Pole
Thermostat
Thermostat
Single Pole
Thermostat
STEP 4
Tuck wires into wiring compartment cover, and replace one screw previously removed. Replace front heater
cover.