A
B
G
D
E
MOUNTING
CLASSIC SINGLE HEAD
M128
Includes
2 mounting bracket screws
2 grommets 1/4"
1 grommet 3/8"
➊
Attach mounting bracket screw to the lowest hole in the tank and leave it
loose enough to slide the mounting bracket under the screw head. Then slide
bracket A under the screw head.
➋
Attach the 2nd mounting bracket screw to secure the top of the mounting
bracket and tighten both screws. DO NOT slide pump into bracket at this time.
NOTE: Motor base stops are located in the mounting bracket. Mount with
directional arrow facing downward.
GROMMETS
➊
Measure and mark the two locations B & C to drill the holes. Location C is for 1/4" grommets only.
➋
Drill proper hole sizes. 3/8" drill bit for 1/4" grommet; 1/2" drill bit for 3/8" grommet.
➌
Install applicable grommets into holes. B & C show the recommended hole locations which may vary based on the application or user's requirements.
IMPORTANT! Failure to clean all debris inside the tank prior to use may lead to pump tube rupture or malfunction.
SUCTION LINE
Parts needed (shipped with pump)
1 20' suction/discharge tubing
1 connecting nut
1 ferrule
1 weighted strainer
SPILL RECOVERY
CLASSIC SINGLE HEAD
M128
NOTE: The spill recovery option can only be used with 1/4" tubing.
➊
Cut a 6" section of 1/4" tubing and insert through the spill recovery grommet C.
➋
Unlatch and remove pump head cover.
➌
Punch out one of two hole plugs using a 7/32" punch F (alternatively, you
can use a 7/32" drill).
➍
Reinstall pump head cover, secure latches.
PUMP ATTACHMENT AND CONNECTIONS
CLASSIC SINGLE HEAD
M128
➊
Slide pump into mounting bracket A.
➋
Insert the end of the tubing extending out from the spill recovery grommet
into the pump head cover but not inside the pump head.
➌
Connect suction tubing to suction side of the pump G with connecting nut and
ferrule. Connection should be "finger tight" only. DO NOT use thread tape or
pipe dope.
➍
Complete the installation with the instructions found in the pump manual.
This information is not intended for specific application purposes. Stenner Pump Company reserves the right to make changes to prices, products, and specifications at any time without prior notice.
S T E N N E R P U M P C O M P A N Y
F
C
3.5"
(9 cm)
ECON
Mounting Kit EC303 required,
sold separately.
➊
Insert suction tubing through the grommet location B until it is 2"-3" from the bottom of the tank.
➋
Remove fill cap.
➌
Reach inside tank and insert 4" of tubing D into the strainer E.
DO NOT slide tubing all the way to the bottom of the weighted strainer. Tubing could become flush
with the nose of the strainer and the pump may not prime due to blockage.
➍
Adjust tubing to maintain weight 2"-3" from the tank bottom.
IMPORTANT! DO NOT allow the weight to rest on the bottom of the tank.
➎
Cut the tubing to leave approximately 9" from location B. The tubing will be connected to the suction side
of the pump head later in the installation.
SVP
SVP
TANK ASSEMBLY INSTRUCTION
Classic Single Head, M128, SVP and Econ Pumps
W RNING
TO BE INSTALLED AND MAINTAINED BY PROPERLY TRAINED
PROFESSIONAL INSTALLER ONLY. READ MANUAL & LABELS FOR ALL SAFETY
INFORMATION & INSTRUCTIONS.
SVP
Includes
2 mounting bracket screws
2 grommets 1/4"
1 grommet 3/8"
➊
Align motor base a as indicated to SVP motor base b. Motor
base a slides and locks into the two tabs.
➋
Secure the motor base a to motor base b with the screw provided.
ECON
Not applicable.
ECON
➊
Slide pump into mounting bracket A.
➋
Connect suction tubing to suction side of the pump G with
connecting nut and ferrule. Connection should be "finger tight"
only. DO NOT use thread tape or pipe dope.
➌
Complete the installation with the instructions found in the
pump manual.
Jacksonville, Florida USA
1 motor base
1 motor base screw (self-tapping)
screw
b
tabs
www.stenner.com
© Stenner Pump Company All Rights Reserved
a
INSTO 012820