TANK SYSTEM INSTALLATION INSTRUCTIONS
Classic Single Head, M128 and Econ pumps
W RNING
TO BE INSTALLED AND MAINTAINED BY PROPERLY TRAINED PROFESSIONAL INSTALLER ONLY. READ MANUAL & LABELS
FOR ALL SAFETY INFORMATION & INSTRUCTIONS.
Plug pump into Grounded Power Outlet; protected by
Ground-Fault Circuit-Interrupter (GFCI).
Shut-off Valve
Flow direction
This information is not intended for specific application purposes. Stenner Pump Company reserves the right to make changes to prices, products, and specifications at any time without prior notice.
S T E N N E R P U M P C O M P A N Y
B
Tank System
Jacksonville, Florida USA
IMPORTANT! The Tank System is equipped with four screws installed
into each side of the mounting bracket to prevent damage during
shipping. Please remove the screws upon installation so that the pump
may be easily removed from the mounting bracket when required.
Install the injector into the pipe or fitting.
Install the discharge line from the discharge side of the pump head to
the injection point.
Install the suction line from the suction side of the pump head to the tank.
Install the Spill Recovery (NOT applicable to Econ Pumps).
NOTE: The spill recovery set-up is optional and utilizes 1/4"
suction/discharge tubing.
• Drill a 1/4" hole in tank surface below pump head .
• Unlatch and remove pump head cover.
• Punch out one of two hole plugs using a 7/32" punch B
(alternatively, you can use a 7/32" drill).
• Reinstall pump head cover, secure latches.
• Cut a 6" section of 1/4" suction/discharge tubing and insert ends
through holes and B.
Connect the power cord to the proper pump control circuit.
Fill the tank with the solution and securely tighten the locking cap.
Prime the metering pump and perform final adjustments, as shown in
the pump manual.
www.stenner.com
INSTS 100820
© Stenner Pump Company All Rights Reserved

Publicidad

loading

Resumen de contenidos para Stenner Pumps Classic Serie

  • Página 1 TANK SYSTEM INSTALLATION INSTRUCTIONS Classic Single Head, M128 and Econ pumps W RNING TO BE INSTALLED AND MAINTAINED BY PROPERLY TRAINED PROFESSIONAL INSTALLER ONLY. READ MANUAL & LABELS FOR ALL SAFETY INFORMATION & INSTRUCTIONS. Plug pump into Grounded Power Outlet; protected by IMPORTANT! The Tank System is equipped with four screws installed Ground-Fault Circuit-Interrupter (GFCI).
  • Página 2 INSTRUCCIONES DE INSTALACIÓN DEL SISTEMA DE TANQUE Serie Clásica de un cabezal, M128 y Línea Econ DVERTENCI INSTALACIÓN DEBE SER REALIZADA Y MANTENIDA POR PROFESIONALES DEBIDAMENTE ENTRENADOS. LEA EL MANUAL Y LAS ETIQUETAS PARA OBTENER LAS INSTRUCCIONES Y LA INFORMACIÓN DE SEGURIDAD. Enchufe el dosificador a un receptáculo con conexión IMPORTANTE! El sistema está...

Este manual también es adecuado para:

M128EconEcon fpEcon vxEcon fxEcon t