UV100A ULTRAVIOLET SYSTEMS
3. Rotate your lamp handle counterclockwise and gen-
tly pull the lamp handle to remove the bulb(s). See
Fig. 10.
Fig. 10. Remove lamp bulb.
4. Holding the lamp handle, wipe the lamp glass using a
soft cloth dampened with glass cleaner. If you touch
the lamp glass with your hands, be sure to clean the
area of any oils left from bare hands. See Fig. 11.
Fig. 11. Clean glass with soft cloth.
5. Also wipe away any dust that may have collected
between the lamp light indicator on the base and the
black lamp base. See. Fig. 12.
Fig. 12. Wipe lamp light indicator base.
68-0248ES—01
M22841
M22843
LAMP LIGHT
INDICATOR BASE
M22845
10
6. Dry bulbs with a clean, dry cloth.
7. Insert the bulb into the base with the lamp light indi-
cator at the eleven o'clock position. Continue pushing
and gently rotating counterclockwise until the lamp
handle inserts fully into the base. See Fig. 13.
Fig. 13. Position bulb for insertion back into
lamp base.
8. Rotate the lamp clockwise until it snaps into place
with the lamp light indicator aligned with the raised
button on the unit cover. See Fig. 14.
Fig. 14. Snap lamp handle into place.
M22847
M22849