Installation
1. Remove the two screws (A1) from the fitting template (A),
then remove the templates, see fold-out page I, fig. [1].
2. Turn the valve stem (C) clockwise to the OFF position.
3. Make sure the water supply is turned on at the service
stop valves (B). Stop valves must be in fully open position
(slots horizontal) for valve to function.
4. The adjustable hot water limit stop (D) is factory set at
neutral position to give maximum outlet temperature, see
fig. [2] and [5].
Please refer to chapter "Maximum hot water limit setting"
for limiting maximum outlet temperature.
5. Install adapter (E) onto the valve stem (C), by placing the
lever stop pin (E1) on top of the "Arrow" ↑ (F), pull on
snap insert (G) and tighten with screw (H).
6. Push cap (I) with drain hole facing down onto the plastic
guide (J) by gently pressing the slotted section (J1) on the
plastic guide.
7. Screw in sleeves (K1) for diverter (K), see fig. [3].
8. Grease seal (M3) with the grease provided, slide the
escutcheon mounting base (M1) on and tighten with
screws (M2).
Do not use excessive force to tighten the screws.
9. Attach escutcheon (M).
10. Fit handle (N) and screw in set screw (N1) with a 2mm
allen wrench, see fig. [4].
11. Screw on diverter knob (K2).
The pressure balancing valve is now ready for use.
If the pressure balancing valve is installed too deep, the
fitting depth can be increased by 1" with an extension set, Part
No. 47 702, see fold-out page II.
Maximum hot water limit setting
The adjustable hot water limit stop (D) is factory set in a
neutral position (0), see fig. [5].
On applications requiring to limit the valve opening from full hot
position, the factory set adjustable hot water limit stop must be
reset as described below.
1. Remove the factory set adjustable hot water limit stop (D),
see fig. [6].
2. Slide the adapter (E) onto the valve stem (C), by placing the
lever stop pin (E1) on top of "Arrow" ↑ (F), see fig. [5] and
fold-out page III fig. [7].
3. Turn the adapter (E) counterclockwise until the outlet water
reaches the desired temperature and read the
corresponding number (1 to 10, see fig. [5]) against the lever
stop pin (E1).
4. Close the valve by turning the adapter (E) clockwise and
remove the adapter (E), see fig. [7].
5. Align the white mark (D1) on the limit stop against the
number (1 to 10, see fig. [5]) you have selected on the dial
and slide the limit stop (D), see fig. [8].
6. Proceed to item 5 in chapter Installation.
1
English
Note:
The preset maximum temperature will change if the inlet
temperatures change or the setting of the water heater
thermostat is altered.
Winterizing the system
It is recommended that the "pressure balancing cartridge"
be removed from the valve casting if the system is to be shut
off during the winter.
Maintenance
Check, clean and if necessary, replace parts.
Grease with special valve grease.
I. Pressure balancing cartridge, see fold-out page III
figs. [9] to [11].
1. Loosen set screw (N1) with a 2mm allen wrench and pull off
handle (N), see fig. [9].
2. Screw out diverter knob (K2).
3. Detach escutcheon (M), remove screws (M2) and pull off
mounting base (M1).
4. Shut off hot and cold water stops (B). The slots are vertical
when the stops are in the off position, see fig. [10].
5. Pull off sleeve (I), loosen screws (J2) and detach plastic
guide (J), see fig. [11].
6. Close the valve by turning the stem (O) clockwise. Detach
extension (J3) and stop ring (P) and note position.
7. Loosen the four corner screws (Q1) and remove valve
cover (Q).
8. Pull the pressure balancing cartridge (R) out of the valve
body noting the location of "H" and "C".
9. Remove the check valve inserts (S), see fig. [12].
The pressure balancing cartridge (R) must be replaced as a
complete unit.
Reassemble in reverse order. Ensure that the hot "H" and
cold "C" markings are on the correct side.
Be sure that the stop ring (P) is installed in the position noted
in item 6.
II. Diverter (K), see fold-out page III fig. [11].
Replacement parts, see fold-out page II (* = special
accessories)
Care
Instructions for care of this faucet will be found in the Limited
Warranty supplement.