• Mount the wall plate against the wall and position the silicone
seal behind the wall plate to provide a waterproof seal
between the wall plate and the wall. Leave a drainage point
to allow any residual water to drain away.
• Fix the wall plate c in place.
• Tighten using the nut b.
• Activate the valve several times to stabilise the temperature.
THE INSTALLER MUST ENSURE:
• THE RECESSING AREA IS WATERPROOF TO PREVENT
ANY INGRESS OF WATER;
• ANY WATER ACCIDENTALLY ENTERING THE RECESSING
AREA (E.G. CONDENSATION, RUN OFF, LEAKS, ETC.)
IS NOT STAGNANT AND HAS A DRAINAGE POINT;
• THE INTEGRITY OF THE SEALS BETWEEN
THE STAINLESS STEEL WALL PLATE AND THE WALL
OR THE WALL PLATE AND THE MIXER/TAP AT LEAST
ONCE A YEAR, AND MAKE GOOD IF NECESSARY.
If this advice is not followed, water may leak
into the wall. DELABIE cannot be held responsible
for any ingress.
FOR FURTHER INFORMATION PLEASE CALL TECHNICAL
SUPPORT (SEE BELOW FOR CONTACT DETAILS).
ADJUSTING THE FLOW RATE (fig. I and J)
The flow rate is set at the factory at 3 lpm for washbasins,
6 or 9 lpm for showers (Ref.s fitted with ROUND, TONIC JET
or GYM shower heads are set at 6 lpm) and 9 lpm for urinals.
• Remove the grub screw j using a 2.5mm Allen key.
• Remove the push-button k.
• Unscrew the cartridge l using a 28mm spanner.
• Remove the O ring o underneath the flow rate regulator n.