Delabie TEMPOSOFT Manual De Instrucciones página 11

Griferia temporizada con pulsacion suave
Ocultar thumbs Ver también para TEMPOSOFT:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29
• Remove the regulator n sliding it off the bottom
of the cartridge, then align the marker m on the cartridge
with the desired notch on the flow rate regulator n:
- Notch 1: maximum flow rate
- Notch 6: minimum flow rate.
MAXIMUM TEMPERATURE LIMITER
(on mixers) (fig.G)
The mixer is delivered with the temperature limiter engaged.
For the UK and Northern Ireland market we recommend
installing a thermostatic mixing valve to provide safe,
temperature controlled hot water. Where thermostatic
mixing valves are installed, the temperature limiter
MUST BE REMOVED. To remove the limiter:
• Isolate the water supply.
• Loosen the grub screw at the back of the mixer body
using a 4mm Allen key and remove the temperature selector.
• To remove the coloured limiter d, prise upwards
with a flat-headed screwdriver.
MAINTENANCE
Foreign bodies in the pipework can cause the mechanism
to malfunction. To remove the mechanism (fig. I):
• Remove the grub screw j using a 2.5mm Allen key.
• Remove the push-button k.
• Unscrew the cartridge l using a 28mm spanner.
Automatic shut-off takes too long or there is continuous
flow (fig. K)
• Clean the inside of the delay case t using a clean, dry cloth;
and clean the calibrated groove s with a non-metallic, sharp
point.
• Check that the lip seal q and seat r are in good condition.
• Remember to replace the spring p.
EN

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Temposoft 2

Tabla de contenido