Descargar Imprimir esta página

Gewiss R-EVolution Home Configuración página 14

Ocultar thumbs Ver también para R-EVolution Home:

Publicidad

Idiomas disponibles

Idiomas disponibles

Gewiss
The charge begins when the vehicle sends the start charge signal, either immediately or
deferred.
or the key in position L, limited charge mode.
The current setpoint is limited_current.
The charge begins when the vehicle sends the start charge signal, either immediately or
deferred.
2º -
start_deferred_charge, enabled
finish_deferred_charge, disabled
or the key in position N, nominal charge mode.
The current setpoint is nominal_current.
The charge begins when the vehicle sends the start charge signal, either immediately or
deferred.
or the key in position L, Programmed charge start.
The current setpoint is deferred_current.
The station allows charging to take place when the start time is reached and the session
continues indefinitely until the charging is complete.
If the time programmed is 23:00:00 and the user connects the vehicle at 23:00:01, the vehicle
will not start charging until 23:00:00 the following day.
3º -
start_deferred_charge, enabled
finish_deferred_charge, enabled
or the key in position N, nominal charge mode.
The current setpoint is nominal_current.
The charge begins when the vehicle sends the start charge signal, either immediately or
deferred.
or the key in position L, Programmed charge interval mode.
The current setpoint is deferred_current.
The station allows charging to take place when the start time is reached and stops charging
at the programmed end time. If the charging is programmed to start at 23:00:00 and end at
09:00:00, if the user arrives at 23:05:00, because this time is within the charge interval the
vehicle will begin charging and will end at the programmed time.
4º -
start_deferred_charge, disabled
finish_deferred_charge, enabled
or the key in position N, nominal charge mode.
The current setpoint is nominal_current.
The charge begins when the vehicle sends the start charge signal, either immediately or
deferred.
or the key in position L, Programmed charge end mode.
The current setpoint is deferred_current.
The charge begins when the vehicle sends the start charge signal, either immediately or deferred
and it ends at the programmed end time. Charging will not commence again until the session is
closed and opened again.
It is possible to switch from nominal charge status to limited charge or vice versa at any moment, without the need
to interrupt the charge.
14
Deferred charge in R-EVolution Home
ABA2023IQM05_ - 7.55.4.186.2 - Configuration

Publicidad

loading