Deferred charge in R-EVolution Home
5. Deferred charge in R-EVolution Home
Charging can be programmed or deferred from most modern electric vehicles themselves.
It is recommended to use this feature whenever available.
However, attending to vehicles that do not feature programmed or deferred charging, it is possible
to configure said deferred charge from this charging point in the most versatile and flexible manner
possible.
However, the manufacturer is not responsible for the compatibility of the programmed or deferred
charge with all vehicles, as some models enter standby mode after a specified period of downtime
and can sometimes fail to react to a signal to charge from the charging point.
In such cases, consult with the manufacturer of your vehicle the time limit that the vehicle must
remain on standby before activating the deferred charge, or learn by trial and error.
As mentioned earlier, it is possible to carry out deferred charging in these stations as long as this is activated and
programmed via USB.
In order to activate the charge the start_deferred_charge line and/or the finish_deferred_charge line must be
configured. In these stations it is possible to recharge the electric vehicle with a nominal or limited charge. Both
charging modes can be selected using the key on the side of the station, whereby N is for nominal charge and L is
for limited charge.
However, if deferred charge is activated using a USB memory, it becomes operative. In this case the limited charge
deactivates, replaced by the deferred charge. Therefore, to select the deferred charge on the station, select position
L using the key. Position N can still be used to select nominal charge.
Deferred charge mode is a generic name, because depending on the different configuration possibilities, there are
up to three different modes of deferred charge. They are as follows:
•
Programmed charge start.
•
Programmed charge interval.
•
Programmed charge end.
The following cases of use are possible:
1º -
start_deferred_charge, disabled (by default)
finish_deferred_charge, enabled (by default)
or the key in position N, nominal charge mode.
The current setpoint is nominal_current.
ABA2023IQM05_ - 7.55.4.186.2 - Configuration
Gewiss
EN
ES
FR
IT
13