Eaton E5148C142 Serie Instrucciones De Operación página 2

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6. Setting of the operating mode
6.1 Selection of basic function
After DIP switch "A" has been switched to "ON" for a
short time, one of the basic functions will be displayed
as follows:
programming
programming
routine
routine
Impulse Counter
Timer
6.2.1 Programming routine Impulse Counter
2
programming
routine
Frequency Meter
Operating mode Add:
Adding mode
Permanent signal at count value ≥
preset value or timed signal at
count value = preset value
Reset to zero
Operating mode Sub:
Subtracting mode
Permanent signal at count value ≤
zero or timed signal at count value
≤ zero. Reset to preset value
Operating mode AddAr:
Adding mode
Timed signal at count value =
preset value
Automatic reset to zero
Operating mode SubAr:
Subtracting mode
Timed signal at count value = zero
Automatic reset to preset value
Polarity of the inputs:
pospol: positive polarity (PNP)
sourcing from + 24V
negpol: negative polarity (NPN)
sinking to 0V
Input modes:
E1: INP A = count input
INP B = count direction input
E2: INP A = count input adding
INP B = count input subtr.
E3: Quadrature input
INP A = count input 0°
INP B = count input 90°
E4: same as E3, but with pulse
doubling.
Each pulse edge of INP A will
be counted.
Scaling factor:
0.0001...9.9999
Setting with
and
keys
Factor 0.0000 wonʼt be accepted
Caution! In operating modes Sub
and SubAr (output signal at
count value = zero) the preset
value has to be evenly divisible
by the factor, otherwise the
counter — when reset — will be
set to the next integer multiple of
the factor.
Decimal point
(only optical function)
0
= no decimal point
0.0
= one decimal place
0.00 = two decimal places
0.000 = three decimal places
Permanent signal of the output,
activated at count value ≥ preset
value in adding mode and at
count value ≤ zero in subtracting
mode*
Permanent signal of the output,
will become passive at count
value ≥ preset value in adding
mode and at count value ≤ zero
in subtracting mode**
Timed signal of the output, will
become passive at count value =
preset value in adding mode
and at count value = zero in
subtracting mode**
Timed signal of the output,
activated at count value = preset
value in adding mode and at
count value = zero in subtracting
mode*
Duration of timed signal of the
output can be set from 00.01 s to
99.99 s
* Activation of relay coil or
optocoupler when reaching the
preset value
** Relay coil becomes dead or
optocoupler will be locked when
reaching the preset value.
MN05401009E

Publicidad

Tabla de contenido
loading

Tabla de contenido