6.2.3 Programming routine Frequency Meter
Gate time = within this period the
incoming pulses will be counted
and displayed.
Programmable range from 00.01 s
to 99.99 s
Setting with
00.00 wonʼt be accepted
Polarity of the inputs:
pospol: positive polarity (PNP),
sourcing sensor
negpol: negative polarity (NPN),
sinking sensor
Input modes:
E1: INP A = count input
E2: INP A = count input adding
E3: Quadrature input
E4: same as E3, but with pulse
Scaling factor:
0.0001...9.9999
Setting with
Factor 0.0000 wonʼt be accepted
Decimal point
(only optical function):
0
0.0
0.00 = two decimal places
0.000 = three decimal places
4
and
keys
INP B = count direction input
INP B = count input subtr.
INP A = count input 0°
INP B = count input 90°
doubling.
Each pulse edge of INP A will
be counted.
and
keys
= no decimal point
= one decimal place
Permanent signal of the output,
activated at count value ≥ preset
value*
Permanent signal of the output,
will become passive at count
value ≥ preset value**
Timed signal of the output, will
become passive at count value =
preset value**
Timed signal of the output,
activated at count value = preset
value*
Duration of timed signal of the
output can be set from 00.01 s to
99.99 s
* Activation of relay coil or
optocoupler when reaching the
preset value
** Relay coil becomes dead or
optocoupler will be locked when
reaching the preset value.
MN05401009E