NATURAL GAS CONVERSION

Natural gas conversion must be performed only by your natural gas provider or service
company.
1. Disconnect the regulator hose from the gas valve. See Figure 8.
Figure 8
2. Disconnect the gas tube from the orifice elbow. Remove the two M4 nuts and remove
the orifice older. Replace the propane orifice with the natural gas orifice from the kit
and reinstall the orifice holder. Apply a solution of soapy water to all connections to
check for leaks. If soap bubbles continue to form, the connection has a leak. If a leak
is found, close the main valve and tighten all connections. NEVER USE A FLAME
TO CHECK FOR LEAKS.
3. Stick the conversion label on the rating plate as shown in Figure 9.
Serial Number _________________
CAUTION: The gas pressure regulator provided with this appliance must be used. This regulator is set for an outlet pressure of
This appliance has been converted to use Natural Gas. Input 40,000 Btu/hr.
Max Gas Supply Pressure 7 in w.c. (1.74 kPa) Min. Gas Supply Pressure 5 in w.c. (1.24 kPa)
Minimum clearance from combustible constructions: Sides: 24 in.609 mm. Top 72 in. 1828 mm.
FOR OUTDOOR USE ONLY. If stored indoors, detach and leave cylinder outdoors.
Jul-01-2015
Metal Rating Plate
Model Number: 98900
1.
2.
3.
4.
5.
6.
7.
Figure 17
Figure 9
8
Conversion Label
Conversion Label