Descargar Imprimir esta página

Samoa 404100 Guía De Servicio Técnico Y Recambio página 5

Publicidad

GB
This pump is self–priming. To prime it the first time, you must connect the air supply to the pump and slowly increase the air
pressure from 0 to the desired pressure using a pressure regulator, while keeping the outlet valve (ex. a grease gun) opened. Once
grease starts to come out through the grease gun/ guns, the pump is primed.
Note: It is important that the foot valve does not get in contact with dirty areas, such as a workshop floor, because it may enter
dirt or foreign particles that can damage the seals.
E
Esta bomba es auto-cebante. Para cebarla la primera vez, es conveniente conectar el aire a la bomba incrementando la presión
lentamente desde 0 bares a la presión deseada con el regulador de presión, manteniendo la válvula de salida (Ej. una pistola de
engrase) abierta. Cuando grasa empieza salir de la pistola/ las pistolas, la bomba está cebada.
Nota: Es importante que la válvula de pie no esté en contacto con zonas sucias, tales como el suelo de un taller, porque puede
entrar virutas o partículas que podrían llegar a dañar las juntas.
F
Cette pompe est auto-amorçante: pour l'amorcer pour la première fois, il est préférable de brancher l'air à la pompe en
augmentant progressivement la pression de 0 bar à celle désirée à l'aide du régulateur de pression, tout en maintenant la vanne
d'arrêt (un pistolet à graisse par exemple) ouverte. La pompe sera donc amorcée dès que la graisse sortira du ou des pistolets à
graisse.
Note: Il est primordial que le clapet de pied ne soit jamais posé à même le sol ou au contact de toute autre zone dite "sale" car les
impuretés pourraient sérieusement endommager les joints.
GB
Symptoms
The pump is not working or there is no
grease delivery.
The pump begins to operate very fast.
The pump keeps on operating although
the grease outlet is closed.
Grease leakage through the air outlet
muffler.
Air leakage through the air outlet
muffler.
Diminution of grease delivery.
Diminution of grease pressure.
Samoa Industrial, S.A. · Box 103 Alto Pumarín · 33211 Gijón - Asturias Spain · Tel.: +34 985 381 488 · Fax.: + 34 985 384 163
Operation / Modo de empleo / Mode d'emploi
Troubleshooting / Anomalías y sus soluciones / Anomalies et solutions
Possible Reasons
Not enough air supply pressure
Some outlet line component is clogged or
closed.
There are air pockets in the grease inlet
area.
The drum is empty or the grease level is
beneath the suction tube inlet.
There is a grease leakage in some point of
the outlet circuit.
Impurities in the upper valve or in the foot
valve.
Grease has by-passed to the air motor
caused by worn or damaged seals (33) or O
ring (31).
The suction tube (47) is not enough
tightened to the motor body (15).
The sliding valve (19) does not close
correctly.
The valve support (20) or the spring (25)
are damaged.
The air piston (4) is damaged.
The O ring (6) is damaged.
There are air pockets in the grease inlet
area.
Impurities in the upper valve or in the foot
valve.
The high pressure cylinder (51) or the high
pressure piston (44) is scratched.
Solutions
Increase the air supply pressure
Clean or open the outlet circuit.
Compact the grease.
Replace the drum or lower the suction tube
until the inlet reaches the grease level.
Verify and tighten or repair.
Dismount and clean. Replace in case of
damage.
Replace the worn or damaged parts.
Tight the threaded union. Verify always that
the O ring (31) is in its correct position.
Dismount and clean. Replace in case of
damage.
Replace the items.
Replace it.
Replace the Gland housing assembly.
Compact the grease.
Dismount and clean. Replace in case of
damage.
Replace the items.
R.05/02 840 801