Maintenance - Oreck POD BK51700 Serie Guia Del Usuario

Aspiradoras inalambricas
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

MAINTENANCE

For maintenance, service or warranty questions, please contact an Oreck Customer Care Specialist at 877-533-2019, visit Oreck.com or your local Oreck Dealer.
PROBLEM
POD indicator flashes red.
Speed indicators are both flashing.
POD indicator flashes orange and
motor stops.
Battery indicator flashes red.
Motor does not start when turned
to an ON position.
Battery indicator flashes red & green
13
POSSIBLE CAUSE
Capacity is full.
Brushroll has a stall.
Unit has a clog.
Battery has run out of charge.
Battery temperature is abnormal.
SOLUTION
Turn power dial to OFF position. Insert a fresh refill into case and
restart unit.
NOTE: DO NOT OVERFILL. Refill should be replaced when indicator flashes
red otherwise unit may become damaged. If overfilled, POD indicator will
flash orange and unit will shut down.
Turn dial to OFF position. Remove obstruction from brushroll, if any.
Wait 15 seconds and restart unit. Visit Oreck.com for detailed instructions.
Turn Dial to OFF position.
1. Remove tool & check for clog in nozzle. Clear clog, replace tool, and
restart unit.
2. Check POD Refill. Replace if full.
3. Visit Oreck.com for detailed instructions.
Turn dial to OFF position. Plug unit in to charge. Time to full charge is ≈2.5
hours for rapid charger and ≈5 hours for standard charger.
Ensure unit is in the OFF position and unplug unit from the charger.
Wait 30 minutes and then plug unit back into charger.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pod bk11700 serie

Tabla de contenido