6 Shut-down
When the user accesses the premises, he/she must deactivate the surveillance mode
before the entry time delay expires. If this is not done, an alarm is triggered.
The "Memory symbol (d)" lights up if an alarm has been triggered during the user's
absence.
6.1 Total shut-down:
The deactivation of the total surveillance mode can be carried out using:
1/ The customer code,
2/ The three "Service" codes, but only if these codes provide access to all the
protected areas and do not have limited access only. In this case, the three
service codes have the same possibilities as the customer code.
If the service codes only allow limited access and do not authorise access to the
entire premises, refer to paragraph 6.2.
3/ The six "Sector" codes, but only if your installation does not comprise any
sectors.
In this case, the six Sector codes have the same possibilities as the customer code. If
your installation comprises two sectors, refer to paragraph 6.3.
When the system is shut down completely:
The red indicator light (8) goes out and the green indicator light (7) comes on,
If the option has been programmed, the siren and/or the intercom system output
one audible beep,
The "Total surveillance" symbol (g) goes out,
If the option has been programmed, the control unit sends the deactivation of total
surveillance information to the call centre. When this call has been taken into account, the
control unit outputs a confirmation signal. If this call fails, the control unit outputs an error
signal.
If the control unit is equipped with the radio option, the deactivation of total
surveillance can be carried out by means of a remote control handset or a radio
keypad.
6.2 If the three "Service" codes do not provide access to the entire
premises:
The use of the three service codes causes the deactivation of the partial
surveillance of the installation.
The red indicator light (8) flashes and, if the option has been programmed, the
siren and/or the intercom system output two audible beeps.
If the option has been programmed, the control unit sends the deactivation of partial
surveillance information to the call centre.