unit is replaced, the entire box must be unscrewed and the earth wiring must be disconnected
from the device. Unscrew the screw top (U) and carefully disconnect the lamp holder from the
lamp. Any loose parts, i.e. of the earth etc., must be carefully retained, as they are not supplied
with a new housing or electrical unit. In case of any doubt with regard to the connection, consult a
recognised fitter.
MAINTENANCE/DISMANTLING
Always switch off the power supply during maintenance/dismantling of the device. The special
lamp must be replaced after 4,500 operating hours. Always keep the drawings at hand during
maintenance/dismantling.
1. Unscrew the three-part couplings and drain the water from the device.
2. Open the pipe clips and carefully pull the device from the supports.
3. Unscrew the screw at the top of the device (U), remove the connection of the lamp from the
housing and disconnect the lamp from the yellow lamp holder (V).
4. Then carefully pull the lamp (Q) from the quartz glass (X).
5. If the quartz glass (X) needs replacing, carefully remove it with a large, flat screwdriver (see
drawing 5). Never use force!
6. When re-installing the lamp and/or the quartz glass, the housing must be in a vertical position in
order to prevent damage to the lamp and the quartz glass.
7. Unscrew the screw cap at the bottom of the device. Re-position the quartz glass onto the device.
Ensure that the quartz glass is introduced exactly into the glass holder (Y). Never use force! The
quartz glass is very fragile.
8. The pump can be activated after all the parts have been returned to their original position.
Please pay attention to the correct position of the sealing rings when re-installing the parts.
Check that there is flow and no leakage in the system.
9. Switch the Xclear AOP Compact Ozone & UV-C 75W on. Check whether the lamp (Q) is operating
via the transparent outlet (R) of the unit.
For the safety instructions and terms of guarantee we would like to
refer to the general UV-C manual from VGE International B.V.