Idiomas disponibles

Idiomas disponibles

5.
Place the (4) washers (supplied) between the floor and air compressor feet.
If needed, solid shims may be placed between the washers and floor to
evenly distribute weight on all four feet. See next figure.
6.
Place the (4) 3/8" lag screws through the air compressor feet, washers,
shims, and into the anchors.
7.
Torque 3/8" lag screws to 7-10 ft.-lbs.

Wiring Instructions

GROUNDING INSTRUCTIONS
This product should be connected to a metallic, permanent wiring system, of
an equipment-grounding terminal or lead on the product and comply with
national and local electrical codes.
Refer to the product specification found in the front of this manual for the
voltage and minimum branch circuit requirements.
should be done by a qualified electrician to comply with national and local
electrical codes.
A qualified electrician needs to knows the following before wiring:
1.
The amperage rating of the electrical box should be adequate. Refer to the
product specifications, found in the front of this manual, for this
information.
2.
The supply line should have the same electrical characteristics (voltage,
cycle, phase) as the motor. Refer to the motor nameplate, on side of
motor, for this information.
NOTE: The wiring must be the same as the motor nameplate voltage plus or
minus 10%. Refer to local codes for recommended wire sizes, correct wire
size, and maximum wire run; undersize wire causes high amp draw and
overheating to the motor.
3.
The wiring diagram for the magnetic starter box (if equipped) can be found
inside the magnetic starter box cover.
Electrical wiring must be located away from hot surfaces
such as manifold assembly, compressor outlet tubes,
heads, or cylinders.
Air Distribution System
rating, plastic pipe can burst from air pressure. Use only metal pipe for air
distribution lines.
The next figure represents a typical air distribution system. The following are
tips to remember when setting up the air compressor's air distribution system.
D24225
RISK OF ELECTRICAL SHOCK. Improper electrical
grounding can result in electrical shock. The wiring
Plastic or PVC pipe is not designed for use with
compressed air. Regardless of its indicated pressure
10- ENG