PARAMETER LIST EV3B23
Label
Min.
SP
r 1
CA1
-25.0
CA2
-25.0
P0
0
P1
0
P2
0
P4
0
P5
0
r0
0.1
r1
-99.0
r2
r 1
r5
0
r12
0
C0
0
C2
0
C3
0
C4
0
C5
0
d0
0
d1
0
d2
-55.0
42
Max.
Unit
Def
r 2
°C
2.0
25.0
°C
0.0
25.0
°C
0.0
1
1
1
0
1
0
3
1
2
0
15
°C
3.0
r 2
°C
-2
99.0
°C
8
1
0
1
0
240
min
1
240
min
3
240
s
0
240
min
10
240
min
10
99
h
6
2
0
99.0
°C
12.0
Description
Temperature Set Point
Cabinet sensor calibration
Evaporator sensor calibration
Type of sensor:
0 = PTC
1 = NTC
Decimal point:
0 = No
1 = Yes
Temperature scale:
0 = °C
1 = °F
Evaporator sensor function:
0 = none
1 = defrost & fan management,
2 = fan thermostat,
Display temperature:
0 = cabinet temp.
1 = Set Point,
2 = evaporator temp if P4 = 1 or P4 = 2
Differential
Minimum set point
Maximum set point
Type of function:
0 = cooling
1 = heating
Working set point differential:
0 = asymmetric,
1 = symmetric
Delay on power up
Minimum time compressor remains OFF
Minimum time compressor remains ON
Time compressor remains OFF in the event of
cabinet sensor failure
Time compressor remains ON in the event of
cabinet sensor failure
Defrost interval, (0 = defrost disabled)
Defrost type:
0 = electric,
1 = hot gas,
2 = compressor stop
Defrost termination temperature