Label
Min.
d3
0
d4
0
d 5
-25.0
d 6
0
d7
0
d8
0
d9
-99
d15
0
A1
-99
A4
-99
A6
0
A7
0
A8
0
F0
0
F1
-99
F2
0
F3
0
HE3
0
© TEFCOLD A/S 2017
Max.
Unit
Def
99
min
30
1
0
25.0
°C
0
1
2
1
min
2
2
0
99
°C
0
99
min
0 0
99
°C
8
99
°C
10
240
min
120
240
min
60
240
min
90
4
3
99
°C
5
2
0
15
min
5
240
min
0
Description
Maximum defrost duration if P4 = 1
Defrost duration if P4 = 0 or 2
Defrost activation on power up:
0 = No
1 = Yes
Defrost delay after power up ( if d4 = 1 )
Override display during defrost:
1 = Yes
2 = "dEF"
Dripping time
Kind of defrost interval, the defrost will be activat-
ed when:
0 = controller will stay ON for the time=d0
1 = compressor will stay ON for the time=d0
2 = the evaporator temp will stay below d9 for the
time=d0
Evaporator temp. above which the count of the
defrost interval is suspended (only if d8=2)
Minimum compressor run before hot gas defrost
activation (d1=1)
Temp. below which the low temp alarm is activated
Temp. above which the high temp alarm is
activated
Delay of alarm activation after power up
Temperature alarm delay
Delay of alarm after the last completion of defrost
cycle
Fan management:
0 = OFF
1 = ON,
2 = with compressor,
3 = according to F1
4 = with compressor according to F1
Evaporator fan stop temperature
Stop fan during defrost:
0 = Yes
1 = No
2 = according to F0
After dripping evaporator fan delay
Time interval to "energy saving" mode, 0 = OFF
43