CAUTION
To avoid possible electrical shock, be sure electricity is
turned off before installing Light Bulbs.
▲WARNING
To prevent over-heating or electrical fi res, use ONLY 120
volt–25 watt, GU10 halogen bulbs as specifi ed.
1. Turn off power.
2. Remove burned-out bulb(s). By gently pressing upward
on the bulb, twisting counter-clockwise and pulling out the
bulb. (Figure 1).
3. Firmly seat the new bulbs in their sockets. By aligning
pins with slots in socket, gently pressing upward and
twisting clockwise to seat the bulb.
4. Restore power.
To Order Replacement Bulbs
Contact your retail store and ask for GU10, 25W bulb.
For your own safety TURN OFF power at fuse box or circuit breaker before trouble shooting your fan.
Trouble
1. FAN WILL NOT START
2. FAN SOUNDS NOISY
3. FAN WOBBLES
EXCESSIVELY
4. NOT ENOUGH AIR
MOVEMENT

Replacing Light Bulbs

Trouble Shooting

▲WARNING
Probable Cause
1. Fuse or circuit breaker blown.
2. Loose power line connections to the fan, or loose
switch wire connections in the switch housing.
3. Dead battery in remote control.
1. Motor noise caused by solid state variable speed
control.
1. Setscrew in downrod support is loose.
2. Setscrew in downrod/hanger ball assembly is loose.
3. Hanger bracket and/or ceiling outlet box is not
securely fastened.
1. Check main and branch circuit fuses or circuit
breakers.
2. Check line wire connections to fan and switch wire
connections in the switch housings.
CAUTION: Make sure main power is turned off !
3. Replace with fresh battery.
1. Some fan motors are sensitive to signals from
solid-state variable speed controls. Solid-state controls
are not recommended, choose an alternative control
method.
1. Tighten both setscrews securely in downrod support.
2. Tighten the setscrew in the downrod/hanger ball
assembly.
3. Tighten the hanger bracket screws to the outlet box,
and secure outlet box.
1. If possible, consider using a longer downrod. For
example, use a 12" downrod instead of the 6" downrod
that comes with your fan.
9
Figure 1
Suggested Remedy