To change light output setting:
READ SAFETY INSTRUCTIONS AND CAUTION
STATEMENTS AND COMPLETE INSTALLATION
INSTRUCTIONS ON PAGE 1 BEFORE CHANGING
LIGHT OUTPUT SETTING.
•
NOTE: Fixture switches up in terms of lumen settings; it
starts at medium (200 lumens). If this level is desired, no
adjustment is needed.
•
Locate the dimple at the top of the fixture. (This is called a
lumen adjustment switch locator)
•
Hold magnet on lumen adjustment switch locator for 1.5
seconds to begin programming mode. Remove magnet.
•
Fixture will blink continuously 4x's at full brightness level and
go dark for 2 seconds and then will illuminate at original
factory setting.
•
To switch lumen settings, magnet must be reapplied to
lumen adjustment switch locator for 1.5 seconds and magnet
must be removed for 1 second between switching.
•
NOTE: fixture blinks 1x for the lowest lumen setting; 2x's for
the middle lumen setting, and 3x's for the highest lumen
setting.
•
Once the fixture is set and magnet removed, it stays in
programming mode for 2 minutes.
•
After 2 minutes, the memory is set. The fixture must have
power to it for these 2 minutes for the program memory to be
set.
•
To change the output brightenss, return to programming
mode by holding magnet on magnetic locator for 1.5
seconds.
•
NOTE: Fixture reverts back to original factory setting when
put back into programming mode.
•
NOTE: Once the desired setting is set, mark the level (1, 2,
or 3) with a marker on fixture under the cowl.
LUMEN ADJUSTMENT
SWITCH LOCATOR
SWITCHING
MAGNET
CONFORMS TO ANSI/UL STD. 1838
For warranty information please visit: kichler.com/customer-care/warranty-information/landscape-warranty
PROGRAMMING MODE
Lumen Level Table (For 2700K/3000K)
LEVEL 1
100 Lm
10W Halogen
Equivalent
* DENOTES FACTORY SETTING
Page 2
CERTIFIED TO CSA STD. C22.2 NO. 250.7
We're here to help
LUMEN
ADJUSTMENT SWITCH
SENSOR
SWITCHING
MAGNET
*LEVEL 2
*200 Lm
20W Halogen
40W Halogen
Equivalent
Equivalent
ORIGINAL
PROGRAMMING MODE
4 FLASHES
LEVEL 1
1 FLASH
"LOW"
LEVEL 2
2 FLASHES
"MEDIUM"
(FACTORY SETTING)
LEVEL 3
3 FLASHES
"HIGH"
866-558-5706
Hrs: M-F 9am to 5pm EST
LEVEL 3
400 Lm
IS-16027SS-US