to the wall units. When the appliance has been adjusted,
definitely fix the hood using the screws A (Fig.4). For the
various installations use screws and screw anchors suited to
the type of wall (e.g. reinforced concrete, plasterboard, etc.). If
the screws and screw anchors are provided with the product,
check that they are suitable for the type of wall on which the
hood is to be fixed.
• Fixing the decorative telescopic flue
Take care not to scratch the duct; wear gloves when removing
the protective film. (Fig. 7)
Arrange the electrical power supply within the dimensions of
the decorative flue. If your appliance is to be installed in the
ducting version or in the version with external motor, prepare
the air exhaust opening. Adjust the width of the support
bracket of the upper flue (Fig.3). Then fix it to the ceiling using
the screws A (Fig.3) in such a way that it is in line with your
hood and respecting the distance from the ceiling indicated
in Fig.2. Connect the flange C to the air exhaust hole using a
connection pipe (Fig.4).
Insert the upper flue into the lower flue. Fix the lower flue to
the hood using the screws B provided (Fig.4), extract the upper
flue up to the bracket and fix it with the screws B (Fig.3).
To transform the hood from a ducting version into a filtering
version, ask your dealer for the charcoal filters and follow the
installation instructions.
• Filtering version
Install the hood and the two flues as described in the
paragraph for installation of the hood in ducting version. To
assemble the filtering flue refer to the instructions contained
in the kit. If the kit is not provided, order it from your dealer
as accessory. The charcoal filters must be fitted in the ducting
unit located inside the hood (Fig.6).
USE AND MAINTENANCE
• It is recommended to operate the appliance prior to
cooking.
It is recommended to leave the appliance in operation for 15
minutes after cooking is terminated in order to completely
eliminate cooking vapours and odours.
The proper function of the cooker hood is conditioned by
the regularity of the maintenance operations, in particular,
the active carbon filter.
• The anti-grease filters capture the grease particles
suspended in the air, and are therefore subject to clogging
according to the frequency of the use of the appliance.
In order to prevent fire hazard, it is recommendable to clean
the filter at a maximum of 2 months by carrying out the
following instructions:
- Remove the filters from the cooker hood and wash them
in a solution of water and neutral liquid detergent, leaving
to soak.
- Rinse thoroughly with warm water and leave to dry.
- The filters may also be washed in the dishwasher.
The aluminium panels may alter in colour after several washes.
This is not cause for customer complaint nor replacement
of panels.
• The active carbon filters purify the air that is replaced in
the environment. The filters are not washable nor re-useable
and must be replaced at maximum every four months. The
saturation of the active carbon filter depends on the frequency
of use of the appliance, by the type of cooking and the
regularity of cleaning the anti-grease filters.
• Clean the fan and other surfaces of the cooker hood regularly
using a cloth moistened with denatured alcohol or non
abrasive liquid detergent.
• The illumination installation is designed for use during
cooking and not for prolonged general illumination of the
environment. Prolonged use of the illumination installation
notably reduces the duration of the bulb.
• Replacing halogen light bulbs (Fig. 8).
To replace the halogen light bulbs B, remove the glasspane C
using a lever action on the relevant cracks.Replace the bulbs
with new ones of the same type.
Caution: do not touch the light bulb with bare hands.
•Commands: (Fig.9) mechanical_the key symbols are
explained below:
A = LIGHT
B = OFF
C = SPEED I
D = SPEED II
E = SPEED III
G = MOTOR WORKING indicator
THE MANUFACTURER DECLINES ALL RESPONSIBILITY
FOR EVENTUAL DAMAGES CAUSED BY BREACHING THE
ABOVE WARNINGS.
- 29 -