4. Setting the unique address for the module
Every module connected onto the Velbus system must have a unique address which can be set via the configuration menu.
This is important for the module identification in the system and for the IR transmitter.
MAKE NOTE OF THE ADDRESS OF EACH MODULE IN YOUR SYSTEM
1. Go to the second configuration menu (long press the small button, then press again)
2. Press the upper right "Address" button to display the address menu. ( after 30 seconds of inactivity, the module exits' the menu)
5. Setting the LCD and button backlight features
1. Go to the first configuration menu (long press the small button)
2.
Press the upper right "Display" button ( after 30 seconds of inactivity, the module exits' the menu)
Adjust the contrast using + and -
Press backlight button to change the
backlight intensity manually.
Press LED button to change the button
LED backlight intensity
6
The upper buttons left or right button to select the address digit (blinking digit).
Keep the lower left button pressed, press the lower right button to modify the selected address digit. Select
an address between "00" and "FE". (00= lowest address, FE = highest address )
The small configuration button to quit the address menu.
Press small button
Select if the backlight must dim auto-
matically (ON) or not (OFF), useful if
panel is used in the bedroom .
Next you can set a time for the dimming
period.
Press small button
Using the 4 buttons, select the backlight
time and corresponding:
ON / OFF / LOW / MID setting.
Note: the selected action will only
execute after the set time is crossed.
Press small
button to
EXIT