From this moment onward you can put the meals to cook into the oven. When the oven door is re -
closed, the transition to the next phase will occur automatically (2 bips are emitted).
If the door is opened and closed before the oven reaches the final pre-heating temperature (i.e. before the
2 bips are emitted), the transition to the next phase will occur anyway.
Afterward you have to pass manually to the 2 phase by a long pressing of the key (9) (there is a sound
of 2 bip).
4.5B SET UP A COOKING CYCLE
Set up a cooking cycle is a binding and auto-corrective actions' sequence from top to lower part.
It means that the cooking mode (Time or Core Probe) and the type of temperature's setting (chamber or
delta t) will be not in contradiction and will be always consistent: for example isn't possible setting up a
cooking time mode with a Delta T.
Cooking modes accepted:
- Time and chamber's set point
- Core probe and chamber's set point
- Core probe and Delta T
The cooking mode has the setting up priority. It means that if it's set up the TIME mode and CHAMBER'S SET
POINT is not possible setting up DELTA T mode, infact it starts the alarm's sound. It's necessary to set up
first of all the CORE PROBE mode and after DELTA T mode. The setting up is auto-corrective, it not allows
incongruous set up. For example if core probe mode and delta t mode are set up and after it's set up TIME
mode also will be automatically set up CHAMBER SETPOINT mode.
4.5C TIME COOKING MODE
TIME COOKING mode needs the setting up of the cooking time and after of the chamber temperature. To
set up cooking time press the (4) TIME key (its led begins to blink).
Time is showed in hh.mm. With (13) and (15) it's possible to select a time between 0h .01min and
9h.59min, with 1 min. step length.
It is also possible to set an infinite cooking time, displayed as INF (if INF is selected, the time variable has
an unlimited duration), and a pre-heating mode, displayed as PRE.
The mode for selection is rotation, that is, after 9h. 59min, INF, PRE is shown, and then 0h.01min.
The value is set up by pressing the key (12) ENTER. If you don't press keys, after a fixed time (default
10sec) the value goes back to its previous setting and it not blinks.
The same happens by pressing the key (10) CANC or (4) TIME.
To set up the chamber's temperature press the key (6) CHAMBER TEMP.
Its led begins to blink. Temperature is showed in the unity of measure selected by a parameter.
With (13) and (15) is possible to select a temperature between a min and a max values set up by a
parameter. Value is confirmed by pressing the key (12) ENTER.
After a fixed timeout without pressing keys and without rotating the encoder or by pressing the key (10)
CANC or (6) CHAMBER TEMP. the value goes back to its previous setting and it not blinks.
4.5D CORE PROBE COOKING
Core probe cooking has two different modes: CHAMBER SET POINT and DELTA T. CHAMBER SET POINT
cooking needs first of all the setting up core probe's temperature and after chamber's temperature.
The set up of the core probe's temperature is common to both modes and is done by pressing the key
(5) CORE PROBE. Its led blinks. The display shows the set of the temperature of the core probe in the
unity of measure selected by a parameter.
With (13) and (15) is possible to select a temperature and set up the value by pressing the key (12) EN-
TER. In the same way you can set up chamber's temperature. You have to pay attention that chamber's
temperature has to be higher than core probe ones defined by a parameter fixed by the constructor.
DELTA T cooking needs first of all to set up core probe's temperature and after the difference between
chamber's temperature and core probe's temperature.
The difference between chamber's temperature and core probe's temperature is set up by pressing the key
(7) DELTA T. its led blinks. The display shows the set of the difference. With (13) and (15) is possi-
ble to select a temperature and set up the value by pressing the key (12) ENTER.